WEB600
USER’S MANUAL
VERSION 2.2
SENSAPHONE
®
REMOTE MONITORING SOLUTIONS
Przeglądanie stron 0
1 2 3 4 5 6 ... 56 57

Podsumowanie treści

Strona 1 - SENSAPHONE

WEB600USER’S MANUALVERSION 2.2SENSAPHONE®REMOTE MONITORING SOLUTIONS

Strona 2

10WEB600 User’s ManualInsTallaTIon and ConfIGuraTIonPHYSICAL DESCRIPTIONThe Web600 is housed in a 5.5”w x 3.7”h x 1.4”d enclosure, which can be easily

Strona 3 - Important Safety Instructions

11Chapter 1: InstallationInsTallaTIonThis section provides information on:• Operating environment• Installation• Connecting sensors/Battery backup mod

Strona 4 - FCC Requirements

12WEB600 User’s ManualConneCTInG sensorsThe Web600 is compatible with a wide variety of sensors including normally open/normally closed con-tacts, 2.8

Strona 5 - 1 YEAR LIMITED WARRANTY

13Chapter 1: InstallationNORMALLY OPEN / NORMALLY CLOSED DRY CONTACTSDry contact sources consist of alarm relays or switches that are isolated and hav

Strona 6

14WEB600 User’s Manual4–20MA CURRENT LOOP TRANSDUCERSThe inputs on the Web600 are compatible with transducers that produce an analog output current of

Strona 7 - Table of ConTenTs

15Chapter 1: InstallationBATTERY BACKUP (OPTIONAL)The WEB600 has an optional rechargeable battery backup module available (part #FGD-W610-B) which can

Strona 8

16WEB600 User’s ManualConfiguration page Network Configuration using a Static IP Address:If your network does not support DHCP then your Web600 will s

Strona 9 - ChapTer 1: InsTallaTIon

17Chapter 1: InstallationNOTE: It is highly recommended that you consult all network configurations and settings changes with your Network Administrat

Strona 10 - PHYSICAL DESCRIPTION

18WEB600 User’s ManualINSTALLING THE SENSAPHONE LOCATOR SOFTWAREThe Sensaphone Locator software is used to find your WEB600 on your network. This is c

Strona 11 - InsTallaTIon

19Chapter 1: InstallationUSING THE SENSAPHONE LOCATOR SOFTWARERun the Sensaphone Locator application by double-clicking the Sensaphone Locator icon on

Strona 12 - ConneCTInG sensors

2WEB600 User’s ManualEvery effort has been made to ensure that the information in this document is complete, accurate and up-to-date. Sensaphone assum

Strona 13 - 2.8K/10K TEMPERATURE SENSORS

20WEB600 User’s ManualChapTer 2: sysTeM ConfIGuraTIonInTroduCTIonThe WEB600 is completely programmable from the internal webpage. This makes it easy t

Strona 14 - RELAY OUTPUT WIRING

21Chapter 2: System Configurationsages to all profiles at priority level 1. Then it will wait the duration of the Escalation Delay and send messages to

Strona 15 - BATTERY BACKUP (OPTIONAL)

22WEB600 User’s ManualSMTPThe SMTP (Simple Mail Transfer Protocol) section is where you must configure your e-mail server set-tings. To have the unit

Strona 16 - Configuration page

23Chapter 2: System ConfigurationZone 5 Value .1.3.6.1.4.1.8338.1.1.4.1.1.1.7.48Zone 6 Value .1.3.6.1.4.1.8338.1.1.4.1.1.1.8.48The complete WEB600 OID

Strona 17

24WEB600 User’s ManualChapTer 3: Zone proGraMMInGThis chapter explains how to program the Zone Inputs for monitoring and alarming based on your requir

Strona 18

25Chapter 3: Zone Programming4-20mA type is selected you can enter the appropriate text for the monitored condition (e.g. %RH, PSI, GPM, RPM,…). When

Strona 19

26WEB600 User’s ManualZone scheduleDatalogging Mode: The WEB600 has two modes of data logging for each zone: Continuous or While In Alarm. In Continuo

Strona 20 - InTroduCTIon

27Chapter 4: User ProgrammingChapTer 4: user proGraMMInGThis chapter explains how to setup User accounts including Username, Password, Access Level, E

Strona 21 - System setup screen

28WEB600 User’s ManualUser Programming ScreenAlarm Delivery Schedule: This weekly schedule sets the time period(s) when alarm delivery will be active

Strona 22 - OIDs for Input Values

29Chapter 4: User ProgrammingSMS-TEXT MESSAGE PROGRAMMINGTo configure a SMS-Text Message choose SMS-Text Message from the drop-down list and enter you

Strona 23 - Admin Screen

3 Important Safety InstructionsYour Web600 has been carefully designed to give you years of safe, reliable performance. As with all electrical equipme

Strona 24 - ChapTer 3: Zone proGraMMInG

30WEB600 User’s ManualChapTer 5: hIsTory This chapter explains how to query the Event and Data Log History. The Event Log is a time-stamped list of sy

Strona 25

31Chapter 5: History Alternatively you can Export the results to a file for viewing in another program. Choose the Export file format from the drop-do

Strona 26 - Zone schedule

32WEB600 User’s ManualChapTer 6: operaTIonOnce you have finished installing and programming the WEB600 the unit is fully operational. Be sure to test

Strona 27 - ChapTer 4: user proGraMMInG

33Chapter 6: OperationThe reset time must be set high enough to allow all enabled escalation levels to be notified about an alarm before it is reset.S

Strona 28 - CONTACT PROGRAMMING

34WEB600 User’s ManualChapTer 7: ouTpuT proGraMMInGThe WEB600 includes a relay output that can be used to control a light, siren, or other low voltage

Strona 29

35Chapter 7: Output ProgrammingRELAY OUTPUT WIRINGThe WEB600 includes an SPST relay output that can be used to turn on a light, siren, or other device

Strona 30 - ChapTer 5: hIsTory

36WEB600 User’s ManualappendIx a: weekly TesTInG proCedureWe recommend that you test your Sensaphone weekly to be sure it is functioning properly. Thi

Strona 31 - Chapter 5: History

37Appendix B: AccessoriesappendIx b: aCCessorIesThe sensors listed below are available from Sensaphone, and represent the most commonly used zone devi

Strona 32 - ChapTer 6: operaTIon

38WEB600 User’s ManualappendIx C: Modbus® speCIfICaTIonsInputs TYPE VALID RANGE BASE OFFSETInput Calibration (fixed-point integer) sint16 ±300.00 4x10

Strona 33 - NETWORK SERVICE DISRUPTION

39Appendix C: Modbus® specificationsThe user’s full name string 0 - 32 characters 4x00772Username for login string 0 - 16 characters 4x00796Password fo

Strona 34 - ChapTer 7: ouTpuT proGraMMInG

4WEB600 User’s ManualFCC RequirementsPart 15: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuan

Strona 35

40WEB600 User’s ManualReset the datalogger bit TRUE 0x00257Reset the eventlogger bit TRUE 0x00258System time (string) string Any Time >= 2009 3x002

Strona 36 - 09/19/09

41Appendix C: Modbus® specificationsContactsBASE + (OFFSET * ((PROFILE_NUMBER * 6) + CONTACT_NUMBER))The contact number is as follows: Contact 1 = 0 Co

Strona 37

42WEB600 User’s ManualNON-GENERIC DATATimestampsTimestamps can be decoded using the following equations. “div” means integer division where the remain

Strona 38 - WEB600 User’s Manual

43Appendix C: Modbus® specificationsContact Types:Contact Type Description3 Email or SMS9 SNMP TrapModbus® Configuration:Operating Mode Description0 Mo

Strona 39

44WEB600 User’s ManualappendIx d: speCIfICaTIonsALERT ZONESNumber of Zones: 6Zone Connector: terminal blockZone Types: N.O./N.C. contact, 2.8K Thermis

Strona 40 - Modbus® noTes

45Appendix D: SpecificationsBattery Backup: Optional 2hr battery backup module (Part #FGD-W610-B).ENVIRONMENTALOperating Temperature: 32–122° F (0–50°

Strona 41

46WEB600 User’s ManualappendIx e: oId InforMaTIonWEB 600 OID INFOZONE INFORMATIONZONE NAMES .1.3.6.1.4.1.8338.1.1.4.1.1.1.3.15 ZONE 1 Name .1.3.6.

Strona 42

47Appendix E: OID InformationZONE RECOGNITION TIME (IN SECONDS).1.3.6.1.4.1.8338.1.1.4.1.1.1.3.16 ZONE 1 RECOGNITION TIME.1.3.6.1.4.1.8338.1.1.4.1.1.1

Strona 43 - Summary Web Page Display Mode

48WEB600 User’s ManualREAL TIME ZONE VALUES.1.3.6.1.4.1.8338.1.1.4.1.1.1.3.48 ZONE 1 REAL TIME VALUE.1.3.6.1.4.1.8338.1.1.4.1.1.1.4.48 ZONE 2 REAL T

Strona 44

49Appendix E: OID InformationZONE MAXIMUM VALUES.1.3.6.1.4.1.8338.1.1.4.1.1.1.3.41 ZONE 1 MAXIMUM VALUE.1.3.6.1.4.1.8338.1.1.4.1.1.1.4.41 ZONE 2 MAX

Strona 45 - PHYSICAL

5 1 YEAR LIMITED WARRANTYPLEASE READ THIS WARRANTY CAREFULLY BEFORE USING THE PRODUCT.THIS LIMITED WARRANTY CONTAINS SENSAPHONE’S STANDARD TERMS AND C

Strona 46 - WEB 600 OID INFO

50WEB600 User’s ManualZONE TABLE LOW.1.3.6.1.4.1.8338.1.1.4.1.1.1.3.13 ZONE 1 TABLE LOW.1.3.6.1.4.1.8338.1.1.4.1.1.1.4.13 ZONE 2 TABLE LOW.1.3.6.1.4

Strona 47 - ZONE LOW LIMIT

51Appendix E: OID InformationCURRENT ZONE TYPE.1.3.6.1.4.1.8338.1.1.4.1.1.1.3.92 ZONE 1 TYPE.1.3.6.1.4.1.8338.1.1.4.1.1.1.4.92 ZONE 2 TYPE.1.3.6.1.4

Strona 48 - ZONE MINIMUM VALUES

52WEB600 User’s ManualGAUGE HIGH SETTING.1.3.6.1.4.1.8338.1.1.4.1.1.1.3.34 ZONE 1 GAUGE HIGH.1.3.6.1.4.1.8338.1.1.4.1.1.1.4.34 ZONE 2 GAUGE HIGH.1.3

Strona 49 - ZONE RESET TIME ENABLED

53Appendix F: ThermistorsappendIx f: TherMIsTors2.8K THERMISTOR DATADegrees Celsius Resistance (Ohms)-50 187,625-40 94,206-30 49,549-20 27,180-10 15,4

Strona 50 - LAST ZONE ALARM

54WEB600 User’s Manual

Strona 51 - GAUGE LOW SETTING

55Appendix G: Returning the Unit for RepairappendIx G: reTurnInG The unIT for repaIrIn the event that the WEB600 does not function properly, we sugges

Strona 52 - Profile Escalation Level

56WEB600 User’s ManualappendIx h: TesT loGAlarms

Strona 53 - 10K THERMISTOR DATA

57Appendix H: Test LogAlarms

Strona 54

6WEB600 User’s ManualPARTICULAR PURPOSE AND THE WARRANTY OF NON-INFRINGEMENT AND/OR ANY WARRANTY ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRA

Strona 55 - The unIT for repaIr

7Table of ContentsTable of ConTenTsCHAPTER 1: INSTALLATION ...9INTRODUCTION ...9F

Strona 56

8WEB600 User’s ManualCHAPTER 4: USER PROGRAMMING ...27CONTACT PROGRAMMING .....

Strona 57 - Appendix H: Test Log

9Chapter 1: InstallationChapTer 1: InsTallaTIonInTroduCTIonCongratulations on your purchase of the Sensaphone Web600 Monitoring System. The system is